How do I wire my Additional Pump Module to a previous module?
Wiring of your additional pump module to a previous additional pump module on your Nexus system.
Step 1
To install your module first depower your Nexus unit and confirm all electrical connections from the washing machine are safe. Take the connector kit and install into the correct spaces in the PCB.
Step 2
NO. | NAME |
1 | 240 V AC Supply Voltage OUT |
4 | COMMS OUT |
NO. | NAME |
2 | 240 V AC Supply Voltage IN |
3 | COMMS IN |
Step 3
You can now reattach the covers and run a reconfigure. The steps for this can be found in the following article ‘How do I reconfigure my Nexus System‘.
Keywords
– How do I wire my Additional Pump Module to a previous module?
– Wire additional pump module to previous module
– Wire additional pump module
– Additional pump module
– Wiring